Rotronic Hygrogen2 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Outils Rotronic Hygrogen2. ROTRONIC Hygrogen2 User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 1
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
26.0 000.0499
ROTRONIC AG, CH-8303 Bassersdorf
Tel. +41 44 838 11 44, www.rotronic.com
ROTRONIC Messgeräte GmbH, D-76275 Ettlingen
Tel. +49 7243 383 250, www.rotronic.de
ROTRONIC SARL, 56, F - 77183 Croissy Beaubourg
Tél. +33 1 60 95 07 10, www.rotronic.fr
ROTRONIC Italia srl, I- 20157 Milano
Tel. +39 2 39 00 71 90, www.rotronic.it
ROTRONIC Instruments (UK) Ltd, West Sussex, RH10 9EE
Phone +44 1293 571000, www.rotronic.co.uk
ROTRONIC Instrument Corp, NY 11788, USA
Phone +1 631 427-3898, www.rotronic-usa.com
ROTRONIC South East Asia Pte Ltd, Singapore 339156
Phone +65 6294 6065, www.rotronic.com.sg
ROTRONIC Shanghai Rep. Office, Shanghai 200233, China
Phone +86 40 08162018, www.rotronic.cn
HYGROGEN 2 VERSION2.0
INSTALLATION INSTRUCTIONS
HYGROGEN2 - Version2.0 instruction
Pre-installation notes
A new major version of the HygroGen2 software is now available – version 2.0.
Version 2.0 software is a complete software package, containing standard and
enhanced features. Enhanced features are enabled by typing in an activation
code once the version 2.0 software is installed.
It is strongly recommended all HygroGen2 customers upgrade to version 2.0
whether enhanced features are required or not.
Version 2.0 Standard:
New features - robustness to power outages, improved water level sensor com-
munication and calibration, and touch screen calibration.
Enhancements for Version 2.0
AutoCal, temperature Range Extension and humidity Range Extension. En-
hancements can be activated after installing the Software 2.0. For activation
see section III, Chapter 2.
Embedded HW4 Software
Please note version 2.0 contains an installation of HW4 v3.x which is not
activated by default.
Customers with HygroGen2 version 1.x and HW4 v3.x will need to re-use their
HW4 v3.x license key.
Customers with HygroGen2 version 1.x and HW4 v2.x will need to either:
r "UYA(YGRO'EN(7VLICENSEKEY('(76
r "UY!UTO#ALWHICHINCLUDESA(7VLICENSEKEY
r $OWNGRADETO(76ANDREUSETHEIREXISTING(76LICENSEKEY
Installation of HygroGen2 software version 2.0
;5SINGEITHERDOWNLOADEDZIPkLEORSUPPLIED53"STICK=
HygroGen2 software version 2.0 is available via download from the ROTRONIC
WEBSITE)TNEEDSTOBECOPIEDONTOABOOTABLE53"STICKWITHATLEAST'"SPACE
4HEPROCESSISDESTRUCTIVEANDWILLERASETHECONTENTSOFTHE53"STICKUSED
!LTERNATIVELYA PREMADEINSTALLATION53" STICKCANBEORDEREDFROM YOUR
ROTRONIC dealer.
r 3ECTION)
$ESCRIBESTHECREATIONOFTHEBOOTABLEINSTALLATION53"STICK
r 3ECTION))
$ESCRIBESTHEINSTALLATIONPROCESSONCEYOUHAVETHEINSTALLATION53"STICK
ready/received.
Section I – Creation of installation USB stick
(can be skipped when USB stick HG2-V2.X-UPGRADE is ordered)
Works only with Windows7!
1. A USB drive with at least 4GB of storage space is required for installation.
The drive will be erased during the following process.
&ROM7INDOWS#OMMAND0ROMPT7INDOWS+EY2THENTYPE#-$ENTER
A 4YPEDISKPART.exe
4HISWILLDISPLAYAPROMPT$ISKPART
To list the physical disks attached to your workstation, type “list disk”
B $ISKPARTlist disk
4HE53"DEVICEWILLBEDISPLAYEDASONEOFTHEDISKS
3ELECTTHEAPPROPRIATEDISK-AKESUREYOUDONOTSELECTTHEWRONGDISK
!'"DEVICEBELOWISSHOWNASDISK-"
C $ISKPARTselect disk 1
Verify that the selected disk is the one that you will clean, format, and
activate.
D $ISKPARTdetail disk
#ONkRMTHESELECTEDDISKHASTHEAPPROPRIATEDRIVELETTER
Then clean the disk.
E $ISKPARTclean
Create the partition.
F $ISKPARTcreate partition primary
-ARKTHECURRENTPARTITIONASACTIVE
G $ISKPARTactive
Format the volume.
H $ISKPARTformat fs=fat32
%XIT$)3+0!24
I $ISKPARTexit
9OUR53"STICKISNOWBOOTABLE
2. Download install package
The installation package HygroGen2ver2.0.zip is available from www.rotronic.com
m$OWNLOADSm3OFTWAREAND,ICENSESm3ECTION#ALIBRATION
 %XTRACTTHE:IPkLETOTHEBOOTABLE53"STICK
2IGHTCLICKTHEDOWNLOADEDkLEANDSELECT@%XTRACT!LLANDSELECTTHEROOTOF
YOUR53"STICKEG$<IENOTASUBFOLDER%XTRACTIONMAYTAKESOMETIME
UPTOANHOUR3AFELYEJECTTHE53"STICKWHENDONE
Your stick is now a HygroGen2 (version 2.0) USB installation stick.
Section II - Installation of HygroGen2 version 2.0 from instal-
lation USB stick
9OUWILLNEED A53"KEYBOARDANDMOUSEPLUGGEDINTO THE(YGRO'EN TO
perform the following steps. And make sure your HygroGen2 connected to a
stable power supply.
1. Make a note of existing HW4 software version and serial number.
A "OOTYOUR(YGRO'ENINTHECONVENTIONALMANNER0RESSTHE(7BUTTON
AND@3TART(7
B 3ELECT@!BOUT(7FROMTHE@(ELPMENU
C -AKEA NOTE OF THE (7 VERSIONNUMBERANDSERIALNUMBER)$ WHICH
should be in the format XX YYYYYYYY ZZZZZ.
D #LOSE(7
E )NSERTTHE53"STICKINTOONEOFTHEback ports of the HygroGen2.
F 'OTOTHESETTINGSSCREENANDPRESS5PDATESOFTWARETHENPRESS/+TO
restart your HygroGen2.
2. HygroGen2 version 2.0 installation
4HE(YGRO'ENWILLNOWBOOTWITHA7INDOWS,OADINGSCREENANDLOADWITHA
(9'2/'%.).34!,,!4)/.$2)6%SPLASHSCREEN)TWILLTAKEAFEWMOMENTSTO
initialise all the hardware components.
A .OTETHEWARNINGANDPRESS2%452.
B 4YPE@#;2%452.=TO COPYTHECURRENT(YGRO'EN SETTINGSTOYOUR 53"
INSTALLATIONDRIVEANDCONkRMTHEACTIONTYPE@9;2%452.=
This creates a snapshot of the current HygroGen2 settings, particularly
customisations to the controller settings that may have been tuned uniquely
FORYOURPARTICULARINSTRUMENT!TTHEENDOFTHEINSTALLATIONTHE53"STICK
should be labelled with the serial number of the HygroGen2, and stored
SAFELY4HIS53"STICKSHOULDBEUSEDINTHEEVENTTHEUNITREQUIRESASYSTEM
recovery.
C 4YPEf9f;2%452.=TOINSTALL(YGRO'ENVERSIONSOFTWARE
D #ONkRMNOOTHER53"PERIPHERALSAPARTFROMKEYBOARDMOUSEANDYOUR
53"INSTALLATIONDRIVEAREPLUGGEDIN0RESSANYKEYTOCONTINUE
E 4HEINSTALLATIONPROCESSWILLTHENPROCEEDWHICHWILLTAKEAPPROXIMATELY
30 minutes.
Select appropriate settings:
F !TTHEENDOFTHEPROCESSYOUWILLBEASKEDWHICHSETTINGSYOUWANTTOUSE
Last Used,2ECOVERY2ORDEFAULT$Select ‘L’.
This will use the previous settings loaded on the HygroGen2 IRRESPECTIVE
OFWHETHERYOUPERFORMEDTHECLONEPROCESSINSTEPB
G !CKNOWLEDGETHEWARNING4HENUNITWILLTHENSHUTDOWN
H 2EMOVETHE53"DRIVEANDTURNTHE(YGRO'ENBACKON4HEUNITWILLTHEN
BOOTINTO#/.&)'52!4)/.-/$%
I #HECKTHE4OUCH3CREEN#ALIBRATION AND$ATE4IME AND THE PRESS /+
ORCANCELTOSKIPTHISTOREBOOTTHEMACHINEINTO/0%2!4)/.!,-/$%
The unit will now operate as HygroGen2 standard version 2.0
Section III - HW4 and Enhanced Features activation
1. HW4 activation
HygroGen2 version 2.0 installs HW4 version v3.x. If the code you noted in
3ECTION))STEPCISNOTVERSIONXPROCEEDTOSTEPA/THERWEISESWITCH
ONYOUR(YGRO'ENANDPROCEEDTOSTEPI
A 4OUSE(7YOUHAVEOPTIONS%ITHERYOUCANDOWNGRADETO(7V
buy and upgrade to HW4 v3 or buy the AutoCal enhanced feature set which
includes HW4 v3.
Please note a standard PC HW4 V3 license will not work.
To downgrade to HW4 V2:
B 3ELECTTHEkLEf(7V5PDATEZIPfONYOUR53"STICK
C 2IGHT#LICKTHESOFTWAREPACKAGEANDCLICKh%XTRACTTOvANDCHOOSETHE
ROOTDIRECTORYOFTHE53"STICK
D 3AFELYDISMOUNTTHE53"STICKFROMTHE0#
E /NTHE(YGRO'ENGOTOTHE3ETTINGSPAGETHENSELECT@5PDATE3OFTWARE
FROMTHE@5PDATES@DROPDOWNMENU
F 3ELECT/+TOBOOTTHE(YGRO'ENINTOCONkGURATIONMODE
G /NCETHE(YGRO'ENISINCONkGURATIONMODEINSERTYOUR53"STICKINTO
ONEOFTHEBACKPORTSANDSELECT@5PDATE(7@
H 0RESS/+TOREBOOT
Having obtained a HW4 V3 license key or downgrade to HW4 V2.4, now
enter the HW4 code:
I /NTHE(YGRO'ENPRESSTHE(7BUTTON3ELECT@3TART(7ANDENTERTHE
code.
2. Activate the Upgrade Features (AutoCal and Range Extension),
Obtain an activation code for the desired enhanced features from your
ROTRONIC dealer.
You will need to supply your HygroGen2 serial number (see rear of instru-
ment) when ordering the code.
4OACTIVATETHEUPGRADEFEATURESGOTOTHE3ETTINGSPAGESELECTTHE@5PDATES
DROPDOWNMENUANDCHOOSE@5PGRADE&EATURES4HEGREENLIGHTSWILLLIGHTUP
displaying the upgrade features which will be available immediately.
Vue de la page 0
1

Résumé du contenu

Page 1 - INSTALLATION INSTRUCTIONS

26.0 000.0499 ROTRONIC AG, CH-8303 BassersdorfTel. +41 44 838 11 44, www.rotronic.comROTRONIC Messgeräte GmbH, D-76275 EttlingenTel. +49 7243 383 250

Commentaires sur ces manuels

Pas de commentaire